6.Command Specification
MODE SENSE
6-54
SONY AIT-5 drive SDX-1100V series Ver.1.0
6.8.
MODE SENSE (6/10) 1Ah and 5Ah
Table 6-51: Mode Sense (6) CDB Format
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (1Ah)
1
Reserved DBD
Reserved
2
PCF Page
Code
3
Reserved
4
Allocation Length
5
Control
Table 6-52: Mode Sense (10) CDB Format
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (5Ah)
1
Reserved LLBAA
(0)
DBD Reserved
2
PCF Page
Code
3-6
Reserved
7-8
Allocation Length
9
Control
The MODE SENSE (6/10) commands provide a means to report parameter of default, current and changeable
configuration parameters. They are complementary to MODE SELECT (6/10) commands. The 6-byte and 10-byte
commands can be interchanged.
The format of the data returned is different for the 6-byte and 10-byte commands. See the MODE SELECT (6/10)
commands for the mode header format differences.
LLBAA:
The LLBAA function is not supported. This field must be ZERO. This field is defined for MODE SENSE 10
only.
If this field is not set to 0b for a MODE SENSE (10) command, the command terminates with CHECK CONDITION
status, the sense key set to ILLEGAL REQUEST, the ASC/ASCQ is set to INVALID FIELD IN CDB.
DBD:
A Disable Block Descriptors (DBD) bit of ZERO indicates that the target may return ZERO or more block
descriptors in the returned MODE SENSE data at the target's discretion. A DBD bit of one specifies that the target
will not return any block descriptors in the returned MODE SENSE data.
PC:
The Page Control field indicates the type of page parameter values to be returned to the initiator as shown
below.
Table 6-53: Page Control field values
Bit 7
Bit 6
Parameter Values
Description
0
0
Current Values
This is the normal default situation where the drive returns to the
initiator its current configuration. Page fields not supported are set to
ZERO by the drive.
0
1
Changeable Values
These are any values which a initiator may alter in a subsequent
MODE SELECT command. Any field that the drive allows to be
changed is set to one. Otherwise the field is set to ZERO.
1
0
Default Values
These are the default values on power-up
1
1
Saved Values
Not supported by the drive
Page Code:
This allows the initiator to select any specific or all pages supported by the drive.
Содержание SDX-1100V Series
Страница 8: ...SDX 1100V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 12: ...1 Introduction 1 4 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 30: ...3 Installation 3 8 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 40: ...4 Operation 4 10 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 54: ...5 SCSI Interface 5 14 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 168: ...7 Drive Diagnostics 7 6 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...