READ ATTRIBUTE
6.Command Specification
SONY AIT-5 drive SDX-1100V series Ver.1.0
6-65
6.13.
READ ATTRIBUTE 8Ch
The READ ATTRIBUTE command allows an application client to read attribute values from the Medium Auxiliary
memory (MAM).
Table 6-65: READ ATTRIBUTE command
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (8Ch)
1
Reserved Service
Action
2
Reserved
3
Reserved
4
Reserved
5
Volume Number(0)
6
Reserved
7
Partition Number(0)
8
(MSB)
9
First Attribute ID
(LSB)
10
(MSB)
11
12
13
Allocation Length
(LSB)
14
Reserved
15
Control
If the medium auxiliary memory is not accessible because there is no medium present, the READ ATTRIBUTE
command will be terminated with a CHECK CONDITION status. The sense key will be set to NOT READY and the
additional sense code will be set to MEDIUM NOT PRESENT.
If although medium is present, the Medium Auxiliary Memory is not accessible, the READ ATTRIBUTE command
will be terminated with a CHECK CONDITION status. The sense key will be set to MEDIUM ERROR and the
additional sense code will be set to AUXILIARY MEMORY NOT ACCESSIBLE.
The service actions defined for the READ ATTRIBUTE command are shown in Table 6-66.
Содержание SDX-1100V Series
Страница 8: ...SDX 1100V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 12: ...1 Introduction 1 4 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 30: ...3 Installation 3 8 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 40: ...4 Operation 4 10 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 54: ...5 SCSI Interface 5 14 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 168: ...7 Drive Diagnostics 7 6 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...