6.Command Specification WRITE FILEMARKS
6-108
SONY AIT-5 drive SDX-1100V series Ver.1.0
6.32.
WRITE FILEMARKS 10h
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (10h)
1
Reserved WSmk
Immed
2
(MSB)
3
Number of Filemarks or Setmarks
4
(LSB)
5
Control
The WRITE FILEMARKS command causes the specified number of Filemarks or Setmarks to be written to the
current logical position.
WSmk:
If this bit is set, the drive writes a Setmark to tape instead of a Filemark.
Immed:
If this bit is set, the drive returns status as soon as the CDB has been validated. An Immediate bit of
ZERO indicates that status will not be returned until the operation has completed.
Number of Filemarks or Setmarks:
This is the number of consecutive marks to be written to tape. A value of
ZERO is not considered an error and GOOD status is returned. If this field is set to ZERO, the drive flushes any
data buffer to the tape.
If the Early-Warning is detected while writing the marks, the drive will finish writing any buffered data. The
command will terminate with a CHECK CONDITION status. Within the Sense Data, the EOM bit is set, the Sense
Key field is set to NO SENSE and the Additional Sense Code and Additional Sense Code Qualifier fields are set to
EOM/P detected. The drive will attempt to complete any subsequent WRITE FILEMARKS, returning a CHECK
CONDITION status in each case.
If the drive encounters the physical EOM when attempting a WRITE FILEMARKS, a CHECK CONDITION status is
returned. Within the Sense Data, the EOD and Valid bits are set and the Sense Key field is set to VOLUME
OVERFLOW. The Information field contains the residue count and the Additional Sense Code and Additional
Sense Code Qualifier fields are set to EOM/P Detected. The tape is physically positioned at EOM/P.
Содержание SDX-1100V Series
Страница 8: ...SDX 1100V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 12: ...1 Introduction 1 4 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 30: ...3 Installation 3 8 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 40: ...4 Operation 4 10 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 54: ...5 SCSI Interface 5 14 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 168: ...7 Drive Diagnostics 7 6 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...