10.APPENDIX C: ASC & ASCQ for AIT (Sony Unique)
SONY AIT-5 drive SDX-1100V series Ver.1.0 10-1
10. APPENDIX C: ASC & ASCQ for AIT
(Sony Unique)
ASC and ASCQ Assignments for AIT drive (Sony Unique)
Numeric Order
BYTE
12
13
DESCRIPTION
83h 00h Reserved
83h 01h MIC
Header
Error
83h 02h No
MIC
Detected
83h 03h MIC
Checksum
Error
83h
04h
MIC out of memory
83h
05h
No Data Body Detected in the MIC
83h 06h MIC
Read
Error
83h 07h No
Cassette
Detected
83h
08h
MIC is not formatted yet
83h 09h MIC
Write
Fault
83h
0Ah
Requested address is write protected on the MIC
83h
0Bh
MIC is broken
83h
0Ch
MIC format type is undefined
83h
0Dh
MIC capacity field indicates illegal value. Acceptable value is 2Kbytes, 4Kbytes, 8Kbytes.
The drive will handle the MIC is 2Kbytes, when capacity field indicates illegal value.
83h 0Eh
:
Reserved
83h 7Fh
83h 80h Partition
count
exceeded
83h 81h Reserved
83h 82h Reserved
83h
83h
MIC is exist but is not used
83h 84h
Reserved
83h 86h
83h
87h
Broken MIC is loaded in AIT mode
83h 88h Reserved
83h
89h
User Volume Note Size mismatch
83h
8Ah
User Partition Note Size mismatch
83h 8Bh
:
Reserved
83h 96h
83h
97h
Current Partition is not the last partition.
83h
98h
Cannot append the new partition, because the remaining capacity too short.
83h
99h
Cannot delete partition, because the indicated partition number is not appropriate.
83h
9Ah
Encounter the EOT while creating the new partition, append partition command is not
completed. (If a drive misleads the tape capacity by some reason, format command will be
failed on the way. In case of the situation, the Last Partition Number must hold the Last
Valid Partition Number, because it is reasonable and time saving. )
83h
9Bh
Cannot format tape because real tape capacity is exceeded.
83h
9Ch
Cannot append new partitions because the MIC is out of memory.
83h 9Dh
:
Reserved
83h FFh
Содержание SDX-1100V Series
Страница 8: ...SDX 1100V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 12: ...1 Introduction 1 4 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 30: ...3 Installation 3 8 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 40: ...4 Operation 4 10 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 54: ...5 SCSI Interface 5 14 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 168: ...7 Drive Diagnostics 7 6 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...