READ BLOCK LIMITS
6.Command Specification
SONY AIT-5 drive SDX-1100V series Ver.1.0
6-69
6.14.
READ BLOCK LIMITS 05h
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (05h)
1
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Control
The READ BLOCK LIMITS command requests that the drive return its limits for Block Length. The READ BLOCK
LIMITS data shown below will be sent during the DATA-IN phase of the command. The command does not reflect
the currently selected block size, only the available limits. MODE SENSE returns the current block size. 2 bytes is
the minimum and 8 Mbytes byte is the maximum block size which the unit can support.
Table 6-71: READ BLOCK LIMITS Data
Bit
Byte
7 6 5 4 3 2 1 0
0
Reserved Granularity(02h)
1
(MSB)
2
Maximum Block Length Limit (80 00 00h)
3
(LSB)
4
(MSB)
Minimum Block Length Limit (00 04h)
5
(LSB)
GRANULARITY
: This field indicates the block size granularity of the logical unit and the recording format. For this
logical unit, the value is 2, indicating a granularity of 2**GRANULARITY.
The
maximum block length limit
and
minimum block length limit
field values are shown in Table 6-71.
Содержание SDX-1100V Series
Страница 8: ...SDX 1100V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 12: ...1 Introduction 1 4 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 30: ...3 Installation 3 8 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 40: ...4 Operation 4 10 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 54: ...5 SCSI Interface 5 14 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...
Страница 168: ...7 Drive Diagnostics 7 6 SONY AIT 5 drive SDX 1100V series Ver 1 0 This page intentionally left blank ...