3. Camera Operations: Operations on the Home Screen of the Sub Display
46
Item
Description
Exposure Index
Sets the EI value. You can change the Base ISO setting by pressing the
Change Base button (ITEM key 4) and then simultaneously pressing the two
Change buttons (ITEM key 1 and ITEM key 3) on the subsequent screen. The
available settings vary as follows depending on the Base ISO setting.
MPC-3628
Base ISO 800:
200EI/250EI/320EI/400EI/500EI/640EI/
800EI
/1000EI/1250EI/
1600EI/2000EI/2500EI/3200EI
Base ISO 3200:
800EI/1000EI/1250EI/1600EI/2000EI/2500EI/
3200EI
/4000EI/
5000EI/6400EI/8000EI/10000EI/12800EI
MPC-3626
Base ISO 500:
125EI/160EI/200EI/250EI/320EI/400EI/
500EI
/640EI/800EI/1000EI/
1250EI/1600EI/2000EI
Base ISO 2500:
640EI/800EI/1000EI/1250EI/1600EI/2000EI/
2500EI
/3200EI/4000EI/
5000EI/6400EI/8000EI/10000EI
Gain
Sets the base sensitivity.
–6dB/–3dB/
0dB
/3dB/6dB/9dB/12dB/15dB/18dB
[Note]
Configurable only when an RM-B170 or other remote control unit is connected and
Technical > Special Configuration > RM/RCP Paint Control (page 91) is set to On in
the full menu.
Shutter
Sets the electronic shutter angle/shutter speed.
Press the Step/Cont. button (ITEM key 1) to switch between step and
continuous selection methods.
Step: Select from up to 16 preset values registered as shutter steps. You can
press the Step Edit button (ITEM key 4) to change any setting from the
preset value after selection.
Displays the following selection options depending on the Technical >
System Configuration > Shutter Mode (page 87) setting in the full
menu.
Angle: Shutter angle indicator
Default selection options
360/180/172.8/144/90/45/22.5/11.2/5.6
Speed: Shutter speed indicator
Default selection options
1/24, 1/25, 1/30, 1/50, 1/60, 1/100, 1/120, 1/250, 1/500, 1/1000, 1/2000
1)
[Note]
The default speed values for different Project Frame Rate (page 54) settings
are given below.
23.98/24: 1/24, 25: 1/25, 29.97: 1/30, 47.95: 1/48, 50: 1/50, 59.94: 1/60
Cont.: Select an angle/speed within the supported range.
Item
Description
ND Filter
Sets the ND filter position. The following settings are available.
Clear
/0.3/0.6/0.9/1.2/1.5/1.8/2.1/2.4
LUT
Configures settings related to the LUT to apply to the output video. The
settings will vary depending on the Technical > Special Configuration > RM/
RCP Paint Control (page 91) setting in the full menu.
SDI 1/2
When RM/RCP Paint Control is set to Off: Log/
Look
Selects the LUT to apply to the SDI 1/2 output image.
When RM/RCP Paint Control is set to On:
Log
/HLG(Natural)/HLG(Live)/
User Gamma
The SDI 1/2 output image setting is display only, because it is
determined by the Project category > Input Color Space setting in the
menu.
SDI 3/4
When RM/RCP Paint Control is set to Off: Log/
Look
Selects the LUT to apply to the SDI 3/4 output image.
When RM/RCP Paint Control is set to On:
Log
/HLG(Natural)/HLG(Live)/
User Gamma
The SDI 3/4 output image setting is display only, because it is
determined by the Project category > Input Color Space setting in the
menu.
Monitor
When RM/RCP Paint Control is set to Off:
Selects the LUT to apply to the Monitor output image.
The settings change as follows depending on the Project category >
Input Color Space setting in the menu.
S-Gamut3.Cine/SLog3 or S-Gamut3/SLog3: Log/
s709
/R709(800%)/
Look
ACEScct: Log/s709/R709(800%)/
Look
When RM/RCP Paint Control is set to On:
Selects the type of Monitor output image.
The settings change as follows depending on the Project category >
Input Color Space setting in the menu.
S-Gamut3.Cine/SLog3 or S-Gamut3/SLog3:
Log
/R709(800%)
HLG(Natural):
HLG(Natural)
/R709(800%)
HLG(Live):
HLG(Live)
/R709(800%)
Rec.2020/User Gamma:
User Gamma
/R709-Like
Rec.709/User Gamma: User Gamma