24
Port Screen
Makes settings for each port of the unit.
Record tab
Port information
Displays the operating status of the selected port. The
display is the same as on the Home screen.
Option
Record File Naming
Selects the file naming convention for automatically
generated files.
• File + Sequential: Assigns a sequential number.
• CCU Serial No. + Time: Uses the date and time of
recording for the file name.
• User Specified Name: Allows the user to specify a 1 to 8-
character prefix for the file name.
User Specified Name
Sets the 1 to 8-character prefix for the names of recorded
files. Enter an arbitrary string in the text box or select a
prefix from the drop-down list.
[Record File Naming] must be set to [User Specified Name]
in order to enable this setting.
TC
Makes timecode settings.
TCG Source
Selects the source signal for synchronizing the internal
timecode generator.
• Internal-Preset
• External-LTC
REGENE Source
Selects the signal to regenerate when the timecode
generator is in regenerate mode.
• TC&UB: Regenerates both the timecode signal and user
bit signal.
• TC Only: Regenerates the timecode signal only.
• UB Only: Regenerates the user bit signal only.
RUN Mode
Sets the running mode of the timecode generator.
• Free Run: The timecode advances when the power is on,
regardless of the unit’s operating mode.
• Rec Run: The timecode advances during recording only.
DF Mode
Displays the drop frame mode of the timecode generator or
timer counter.
Timer Select
Displays the time data to display.