![Sony HKCU-REC55 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/sony/hkcu-rec55/hkcu-rec55_operating-instructions-manual_393466020.webp)
20
Setup tab
Makes basic operating mode settings of the unit.
System Parameters
Frame PB Mode
Selects the playback mode during variable speed playback.
• Field: Field playback
• Frame: Frame playback
File Delete Mode
Selects whether to delete a file if the Delete command is
received for a file for which playback or file transfer (export)
is in progress.
• Inhibit: Prevents deletion of files during playback or file
transfer.
• Permit: For a file during playback, it deletes the file when
the port closes. For a file during file transfer, it stops the
transfer and then deletes the file.
TC Setup
DF Mode
Sets the drop frame mode of the timecode generator or
timer counter.
• NDF
• DF
This setting is valid only when the frame frequency is
29.97 Hz.
Timer Select
Selects the time data to display.
• TC
• UB
• TM1
• TM2
TC Out
Selects the signal to output from the TIME CODE OUT
connector on the rear panel. This is set to Through (fixed) in
the current version.
Character
Character On/Off
Selects whether to display superimposed character
information, such as the timecode, on the monitor signal.
• Off
• On
Character Size
Sets the display size of character information.
• Small
• Medium
Vertical Position
Sets the vertical display position of character information.
• 0 (top) to 22 to 255
Horizontal Position
Sets the horizontal display position of character
information.
• 0 (left) to 128 to 255
Note