7 - 3
SONY SDT-10000/SDT-11000 DDS Tape Drive
7. Diagnostics
In the SCSI-2 mode, the Page Format (PF) bit is one, and the Parameter List Length is 9, the Parameter List in this case
is 9 bytes long and will be of the form:
Bit
7
6
5
4
3
2
1
0
Byte
0
Page Code (81h)
1
Reserved
2
(MSB)
3
Page Length (00 05h)
(LSB)
4
Diagnostic Test Number
5
Break
Loopcount
6
Parameter A
7
Parameter B
8
Parameter C
Table 7-2: SEND DIAGNOSTIC Parameters - SCSI-2
Break: indicates how to terminate the loop count should an error occur.
0 = stop on first error
1 = do not stop on error
Loop Count Identifier: The number of times that the test should be repeated before status is returned.
0 = Continuous
1 = run once
2 = run 10 times
3 = run 100 times
4 = run 1000 times
Parameters A, B, C: Any additional parameters required to fully define the diagnostic test.
These parameters are unused and shall be 00h for all diagnostics.