6 - 26
SONY SDT-10000/SDT-11000 DDS Tape Drive
6. COMMAND SPECIFICATION
Supported Parameter Codes in this page are listed below along their meanings:
Table 6-18: Tape Log parameter codes
This information is contained within RAM in the Drive Controller. When a cassette is loaded, the contents of the
System Area are copied into this log. The log is updated as the tape is used and is copied back onto the System Area
when the cassette is unloaded (if the tape is Write enabled).
Note: The System Area only contains ‘previous’ and ‘total’ information - (when the cassette is unloaded, the ‘current’
values become the System Area ‘previous’ values).
The term ‘current’ refers to information generated during the current load of the tape; ‘previous’ refers to information
generated during the last tape load; ‘total’ refers to information generated during the life of the tape since it was first
initialized including the current load.
Use: An estimate of reading and writing performance can be made by the ratios of ‘RAW retries’ to ‘groups written’
and ‘ECC-3 retries’ to ‘groups read’. An indication of tape degradation can be gained by comparing these ratios
for ‘current’, ‘previous’ and ‘total’ entries.
Any attempt to change this page using LOG SELECT will result in a CHECK CONDITION with a Sense Key of
ILLEGAL REQUEST. The current cumulative values will be returned regardless of the Page Control field in the LOG
SENSE CDB.
Parameter Code
Description
Length
001h
Current number of Groups Written
3
002h
Current number of RAW Retries
2
003h
Current number of Groups Read
3
004h
Current number of ECC-3 Retries
2
005h
Previous number of Groups Written
3
006h
Previous number of RAW Retries
2
007h
Previous number of Groups Read
3
008h
Previous number of ECC-3 Retries
2
009h
Total number of Groups Written
4
00Ah
Total number of RAW Retries
3
00Bh
Total number of Groups Read
4
00Ch
Total number of ECC-3 Retries
3
00Dh
Load Count
2
4 (DDS-3 and DDS-4)
4 (DDS-3 and DDS-4)
LOG SENSE