6 - 22
SONY SDT-10000/SDT-11000 DDS Tape Drive
6. COMMAND SPECIFICATION
Bit
7
6
5
4
3
2
1
0
Byte
0
Page Code (02h or 03h)
1
Reserved
2
(MSB)
Page Length (n)
3
(LSB)
4
(MSB)
Parameter Code
5
(LSB)
6
DU (0)
DS (1)
TSD (0)
ETC (0)
TMC (00)
Reserved
LP (0)
7
Parameter Length (m)
8
(MSB)
Parameter Value
n
(LSB)
IMPLEMENTORS NOTE:
Typically, an initiator should first request page zero to determine the list of pages supported by the device.
The page code parameters are a list containing the page codes of the supported pages for the logical unit in ascending
order.
Note that neither Threshold nor Cumulative values have any meaning for this page.
6. 06. 4 Write and Read Error Counters Pages
The Error Counters Pages (Write and Read) are used to report statistical information about Write and Read soft and hard
errors and retries. Each parameter is a counter which is updated by the target every time the corresponding event occurs.
The format of the Error Counters Pages is given below: