2 - 4
SONY SDT-10000/SDT-11000 DDS Tape Drive
2. SPECIFICATION
2. 2 ENVIRONMENTAL SPECIFICATIONS
Note: The specifications which apply when a medium is present may be different than these.
2. 2. 1 Temperature and Humidity Range
Temperature
Operating:
5°C to 40°C ( T<10°C/h)
Non-operating(mech):
-40°C to 70°C ( T<20°C/h)
Non-operating(tape):
-40°C to 45°C ( T<20°C/h)
Humidity
Operating:
20 to 80% RH, non-condensing
Maximum wet bulb temperature=26°C
Non-operating(mech):
5 to 95% RH ( RH<30%/h)
Non-operating(tape):
20 to 80% RH ( RH<30%/h)
2. 2. 2 Altitude
Operating:
0 to 2133 m (0 to 7000 feet)
2. 2. 3 Dust
Operating:
Less than 150 microgram/m
3
Based Sampling period 24 hours
2. 2. 4 Vibration
Operating:
Swept Sine 5 to 500 Hz
@ 0.25 G Peak 1 Octave/min.
3 axis, 3 directions
Non-operating:
Swept Sine 5 to 500 Hz
@ 0.5 G Peak 1 Octave/min.
3 axis, 3 directions
2. 2. 5 Shock
Operating:
No Data Loss
Half Sine
5 G Peak 3 ms
3 axes, 3 directions
Interval 10 seconds
Non-operating:
No Device Damage
Half Sine
90 G Peak 3 ms
(30 G Peak 11 ms)
3 axes, 3 directions