6 - 29
SONY SDT-10000/SDT-11000 DDS Tape Drive
6. COMMAND SPECIFICATION
Supported Parameter Codes in this page are listed below with their meaning:
Parameter Code
Length (bytes)
0001h
Drum revolution minute
3
0002h
Load count
3
0003h
Thread count
3
0004h
Assert count
3
0005h
Cleaning interval (minute)
3
0006h
Power on time
3
0007h
MD serial number
4
0008h
PCB serial number
4
0009h
Drive serial number
4
0011h - 2Eh
Last 30 Mechanism Error Events List
5 x 30
Table 6-21: Supported Parameter Codes
Each Mechanism Error Event is 5 bytes long and has following format:
Byte offset
Meaning
0
Error code
1
Executing Mechanism Commands when error was detected
2 - 4
Timestamp (minute)
Table 6-22: Mechanism Error Event Format
Executing Mechanism Commands
FWD ATF ON
FF
PAUSE
THREAD
TENSION OFF
RVS
REW
UNTHREAD
STOP
EJECT
MD INITIALIZE
0x01
0x07
0x0e
0x0f
0x10
0x11
0x17
0x20
0x21
0x22
0x2A
FWD
LOAD
RE TENSION
RESTART
STOP FF
STOP REW
ASSERT
RELEASE
RE ASSERT
STOP FWD
STOP RVS
0x30
0x31
0x32
0x33
0x34
0x35
0x36
0x37
0x38
0x39
0x3A
LOG SENSE
Содержание DDS-4