7 - 11
7. DIAGNOSTICS
Group Count: This defines the number of groups to be written to or read from the tape.
0 - Write until EOT or Read until EOD/EOM
>0 - Write until count is exhausted or EOM, Read until count is exhausted or
EOD/EOM. If EOM is encountered during Write, EOD will not be written.
In all cases, encountering EOM will be recorded as a hard error.
The Diagnostic result for the Error Rate Test will be as shown in the table below.
Bit
7
6
5
4
3
2
1
0
Byte
0
Reset
Time
Error
Re-Sync
Reserved
Error Set
1
Error Code
2
(MSB)
Actual Group Count
3
(LSB)
4
Diagnostic Test Number (02h or 03h)
Table 7-7: Error Rate Test results
This test will result in a loss of logical tape position and therefore a load should be sent before the drive is used for any normal
reads or writes.