7 - 12
Sony SDT-10000/SDT-11000 DDS Tape Drive
7. DIAGNOSTICS
7. 1. 7. 2 Read Data Exerciser (43h) Diagnostic Parameters
The purpose of this test is to read audio or DDS format data for error rate testing.
Bit
7
6
5
4
3
2
1
0
Byte
0
Diagnostic Test Number (43h)
1
Loopcount
2
(MSB)
3
Number of Frames
4
(LSB)
Table 7-8: Read Data Exerciser Parameters
Number of Frames: The drive will read the number of frames specified in this field.
Execution Time: Number of frames x loopcount x7ms (Maximum 90 minutes,120m)
Bit
7
6
5
4
3
2
1
0
Byte
0
Reset
Time
Error
Re-Sync
Reserved
Error Set
1
Error Code
2
(MSB)
Number of loops executed
3
(LSB)
4
Diagnostic Test Number (43h)
Table 7-9: Read Data Exerciser Result
The results message will contain the number of loops executed during the test.
This test will result in a loss of logical tape position and therefore a load should be sent before the drive is used for any normal
reads or writes.