The AVN-TB20AR and AVN-TB20AD have embedded web servers which
provide easy access to all the configuration options through a web browser.
It also gives access to system information and allows the firmware to be
easily updated when new releases are made available.
To access the embedded web server, the unit needs to be connected to a
network via either of the 2 network ports on the rear panel. The upper port
is the general access Ethernet port and the lower port is the audio over IP
(AoIP) port. By default, both ports are set to static address mode with the
upper port IP address set to 192.168.0.100 and the lower port IP address
set to 192.168.1.100. If the network address mode for the port to be used
has been set to dynamic, the unit will attempt to acquire an IP address from
a DHCP server or auto configuration if no DHCP server is found. The current
IP address of these ports can be accessed by going to the main menu via
the front panel navigation control, and selecting
– see page 53
for details. If a port has yet to acquire an IP address or has failed to link, the
corresponding IP address and subnet mask will show 0.0.0.0. Once the IP
address of the required port is known, simply type this into the address bar
of a web browser. The Device Information page of the connected unit will
be displayed. This is the default page and will always be displayed first
when connecting to the embedded web server. Each page of the web server
shows the intercom name in the upper right hand corner, under the model
label. This makes it easier to identify the connected intercom unit,
especially when configuring multiple units at the same time. The right hand
side of each page has a brief help section that describes the content of each
section.