Front Panel Controls, Connections & Indicators
Status Indicators
The RGB status indicators are located on the le� side of the front panel.
AoIP
Indicates the status of AoIP services on the network as follows:
Green
All transmit AoIP streams are available and at least one
external AoIP service is available.
Amber
Either the transmit AoIP streams have not started or there
are no external AoIP services available.
Off
The transmit AoIP streams have not started and there are
no external AoIP services available. The indicator will
also be off if there is no link on the AoIP network port
(lower network connector).
The AoIP network interface is configured via the embedded web server. See
the
on page 29.
Ethernet
Indicates the link status of the Ethernet network port (upper network
connector) as follows:
Green
The link is up.
Off
The link is down.
The Ethernet network interface is configured via the embedded web server.
See the
on page 29.
Talk
Illuminates green if an intercom call or page is ac�ve.
AGC
Indicates the status of the automa�c gain control as follows:
Green
The AGC is enabled.
Red
The audio source level for one of the outputs is too high
and is being limited. The monitored outputs are outputs
1-3 on the rear panel, the headphone/headset output and
the speaker output.
Clock
Indicates the status of PTP clock as follows:
Green
The unit is a PTP slave with a clock offset of less or
equal to ±1µs or the unit is the PTP master.
Amber
The unit is a PTP slave with a clock offset of between
±1µs and ±10µs.
Flash Amber
The unit is in a listening state and is not yet ac�ng as the
master or a slave.
Red
The unit is a PTP slave with a clock offset of greater
than ±10µs.
Flash Red
The unit is a PTP slave and no master is available.
AC PSU
Indicates the status of the internal AC-DC power supply as follows:
Green
AC-DC generated voltage is within normal opera�ng range
of +11V to +13V. This is the normal condi�on.
Amber
AC-DC generated voltage is less than +11V or greater than
+13V. This indicates a warn condi�on.
Red
AC-DC generated voltage is less than +10V or greater than
+14V. This indicates a fault condi�on.