ATTENTION
During calibration the SPA-ribbon-sensor must be dry and free of snow and
ice!
All sensors must be connected and active during calibration!
10.4.3 Zero test and adjustment
Follow the instructions below to perform a zero-test and -adjustment:
1. Install the SPA-2 as described in Section
.
2. Connect the SPA-2 controller to your PC and a power-supply with the specified rating.
3. Open the Commandersoftware and establish a connection to the SPA-2 as described in
.
4. Download the parameter list and open
in the Technics menu.
5. For each sensor click
Test sensor
. The SPA-2 performs a measurement and displays the results
in a pup-up window.