0XRB|!
Answer:
0B=300|<CR><LF>
Setting of measurement interval to 60 s (in this example menu item B)
0XWB=60|!
Answer:
0B=60|<CR><LF>
Read and write a parameter with options
Changing the measurement trigger (in the following example menu item A) from
interval
to
SDI-
12/RS485
:
EXAMPLE
0XRA|!
Answer:
0A=1|<CR><LF>
0XWA=3|!
Answer:
0A=3|<CR><LF>
Read and write a parameters of a table
Some SOMMER sensors are equipped with multiple transducers and their settings are listed in a
table (see example below). A value within such a table is addressed by its row-index (01, 02 …) and
column-index (A, B …). A corresponding SDI-command has the following format:
EXAMPLE
In this example of a snow scale the value in row 01 and column B of the para-
meter D-D-E is changed to -1.4.
0XWDDE01B=-1.4|!
Answer:
0DDE01b=-1.4|<CR><LF>
Adopt settings
Some settings need to be adopted with the command
aXW_ts|!
, with
a
the sensor address. It is
recommended to issue
aXW_ts|!
after each configuration change.
11
S
er
ia
lc
o
m
m
u
n
ic
at
io
n
74
Manual
Содержание SPA-2
Страница 48: ...9 Support software Commander 48 Manual...