3 How do I start?
Follow the steps described below to set the basic configurations and to acquire the first meas-
urement results.
NOTE
Perform the first start-up in your lab or office before installing the
equipment in the field!
3.1
Connect the SPA-2 to a PC
1. Install the Commander support software (see
2. Connect the yellow and gray wire of the sensor cable to the USB to RS485 isolated converter
cable and plug it into your PC as illustrated in the figure below.
3. Connect a 9...28 VDC power supply to the SPA-2
4. Start the Commander software.
5. Click on
Communication assistant
on the right-hand side of the Commander window and fol-
low the instructions. During this procedure the communication assistant will search for con-
nected devices. Upon successful completion, the new connection is added to the connections
list (tab
Connections (F8)
).
6. In the
Communication
Section at the right-hand side of the Commander window select Mode
Connection
and the previously created connection from the drop-down list.
7. Click
Connect
to establish a connection with the SPA-2. If the connection was successful a
green icon is displayed at the top-right corner of the Commander window.
8. Select the tab
Parameters (F2)
and click
Download parameters from device
on the left side of
the Commander-window. The complete parameter list is transferred from the sensor to your
PC and displayed in the
Parameter
window.
Figure 2
Wiring of the SPA-2 to a PC
3
H
o
w
d
o
Is
ta
rt
?
12
Manual
Содержание SPA-2
Страница 48: ...9 Support software Commander 48 Manual...