66
S-MEA
The name of an internal system variable, the connection port of the selected analog sensor, or the
position of the measurement value within the string returned by the selected digital sensor. See
for the available options.
S-ADD
Contains additional commands which are sent with a standard request to a sensor (or source), or which
provide additional options for controlling measurements and handling results. The available com-
mands depend on the settings in
Function S-TYP
S-ADD
Description
SUM
all
NR
No reset of summed variables at daily reset event
MR
Monthly reset of summed variables
DD
Double data for summed variables at reset event; old and new
values are stored
TR
Threshold reset: for summed variables with
; sum is re-
duced by limit after limit violation
all
SDI12
_Cn
Concurrent measurement command for measurement cycle n
CCn
Concurrent measurement command with CRC for measurement
cycle n
_Mn
Measurement command for measurement cycle n
MCn
Measurement command with CRC for measurement cycle n
_Rm
Read command for data m
RCm
Read command with CRC for data m
n
Number of SDI-12 measurement cycle
m
Number of SDI-12 output line
all
COUNT
SW
Switched direction of shaft/impuls encoder
SBP, MIO
SCx
Subchannel for MDL compatibility
TD
Trigger data of a SBP or MIO device
MIO
TF
Trigger fake
all
all
SY
Synchronous storage: variable that is normally stored asynchro-
nously is stored in the main storage interval.
AS
Asynchronous storage: variable that is normally stored synchro-
nously is stored in the
SXaa
auxiliary storage interval: where
aa
is the auxiliary interval to
use
ST
Triggers an action if the measurement value falls BELOW the
specified limit set in
MAxx
Moving average of
xx
values, where
xx
is 5, 12, 24, 48, 96
EX
Exponential: value is put to the power of
e
PTy.y
Potential: value is put to the power of
y.y
GS
Limit status of the recycled variable