69
K
Standby, start time
08:00:00
L
Standby, duration
01:00:00
M
IP Call server
mds.sommer.at
N
IP Call port
4647
O
IP Call interval
00:01:00
M
E-Mail/SMTP
I-A
Modem functionality
Setting
Description
on
Modem is active
off (default)
Modem is inactive
I-B
Modem config
Configuration of the MRL-7 modem for data transmission.
A
SIM pin
-1
B
Net type
auto
C
Foreign operator mcc&mnc
D
Operator select
auto
E
APN address
F
APN username
G
APN password
H
Custom command 1
I
Custom command 2
I-B-A
SIM pin
The PIN of the SIM card. If set to
-1
, no PIN is required.
Value range
Default
Unit
-1…9’999
-1
-
The PIN cannot be changed with the MRL-7. Use a different device, e.g. mobile phone, for this task.
!
Attention
If the wrong PIN is entered, the SIM card will be locked after three consecu-
tively attempts to transfer data.
I-B-B
Net type
The telecommunication standard used for data transmission.
Setting
Description
auto (default)
The telecommunication network is selected automatically.
3G
Only 3G telecommunication networks are used to transfer data.
2G
Only 2G telecommunication networks are used to transfer data.