This device complies with FCC RF radiation exposure limits set forth 

for general population (uncontrolled exposure). This device must be 

installed to provide a separation distance of at least 20cm from all 

persons and must not be collocated or operating in conjunction with 

any other antenna or transmitter.

 

 

Содержание LT2

Страница 1: ...omplies with FCC RF radiation exposure limits set forth for general population uncontrolled exposure This device must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter ...

Страница 2: ...nstructions 3 1 3 Battery Safety 3 1 4 Warning to users in the United States 4 1 5 Warning to users in Canada Attention pour les utilisateurs au Canada 4 2 Introduction 6 3 Necessary equipments 6 4 Configuration of the logger using the software IJITempLab 4 7 7 4 1 Launch the software IJITempLab 4 7 and connect to the data logger to configure 7 4 2 Displaying the measures 8 4 3 Data export 9 4 4 M...

Страница 3: ...electrostatic loads before opening and manipulate the devices by touching a metallic surface linked to the Earth 1 3 Battery Safety This product contains a lithium battery that must be disposed of properly Please follow the battery safety items below Do not dismantle open or shred secondary cells or batteries Do not expose cells or batteries to heat or fire Avoid storage in direct sunlight Do not ...

Страница 4: ...m IJINUS Unauthorized modification may void the equipment authorization from the FCC and will void the IJINUS warranty This device complies with FCC RF radiation exposure limits set forth for general population uncontrolled exposure This device must be installed to provide a separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other ...

Страница 5: ...ques de brouillage radioélectrique à l intention d autres utilisateurs il faut choisir le type d antenne et son gain de sorte que la puissance isotrope rayonnée équivalente p i r e ne dépasse pas l intensité nécessaire à l établissement d une communication satisfaisante Cet appareil doit être installé de manière à assurer une distance de séparation d au moins 20 cm avec toutes les personnes Il ne ...

Страница 6: ...sary equipments LT2 temperature M0C0000 2 WIJIKEY 2 A0G00010 Data Logger Programming kits including Non rechargeable lithium the software IJITempLab battery 3 6V 2 6Ah for LT2 The LT2 data logger has an internal battery To check or activate the radio connection you can press the front button The LED flashes green by period every x seconds depending on configuration This LED indicates that a radio ...

Страница 7: ...ance is needed between the Wiji antenna and the datalogger for a correct radio connection Click the Connect button so the software recognize the Wiji as a radio access point If it doesn t work you can install the drivers from the top main menu then Tools and Install the Wiji driver Once connected you have to click the Refresh visible sensors and choose from the list the available sensors nearby Th...

Страница 8: ...ill appear confirming the recording state 4 2 Displaying the measures From the graph and or list of data you find the tab Export the measures with the choice of different files format and style You have 3 options to retrieve the data Once retrieved they are displayed on the graph You can zoon into the graph with your cursor clicked By passing your cursor along the curve you are able to check the m...

Страница 9: ...e different ways of exporting the data You can export the measures directly from the graph by right clicking on it choosing from this menu Export to csv The same option is available from the top menu Choose File and Export to csv Finally to automatically export the data choose a directory like bellow example 4 4 Menu options From the File menu you can Export data to csv Import a configuration file...

Страница 10: ...3 30 Customer Service 33 2 98 09 03 32 sav ijinus com 10 From the Tools menu you can Install the Wiji driver or uninstall it Change the sensor resolution as desired Change the memory recording mode Retrieve a sensor configuration From the View menu you can hide the parameters to reveal the graph only in a bigger size ...