93
Additional Cleaning
Every 600-800 kg of pellets, an additional cleaning should be carried out.
Open the door, clean the debris that may be on the grate before removing it, remove
the grate, drawer and burner, once removed, remove the baffle plate, which is on top
of the combustion chamber (figure 59).
Figure 49
–
Removal of the baffle plate
Remove the vermiculite plates lining the inside of the combustion chamber, first
remove the sides and then the back. This shows the parts separating the combustion
chamber from the smoke passage (Figure 60).
Figure 50
–
Combustion chamber separators
Using a nº5 hex wrench, remove the two DIN912 M6x12 screws securing the lower
spacers (Figure 61). Once removed, the top separators are easily removed, the smoke
Содержание EARTH 9KW