List Alarms / malfunctions / recommendations
All alarms cause the machine to shut down with information about the error and
activation of the alarm led. It will be necessary to reset the alarm and restart. To reset
the machine, press the "On/Off" button for 3 to 4 seconds until you hear a beep,
accompanied by the message "Reset alarms in progress";
If the reset is successful, there will be new information - Reset alarms successful
In the Off state if for any reason the smoke temperature rises above 85ºC (Th01) the
stove enters the off mode.
Alarm
Code
Cause and Resolution
Excess
temperature in
the pellet tank
Er01
110 °C, even when the
equipment is off
- Room fan not working - call
for service
- Thermostat defective - call
for service
- Machine with defective
ventilation
Smoke pressure
switch alarm
Er02
Door open, no depression
or extractor failure for 180
s
Only visible if puller is set
to On
- Close the door and remove
the faulty pressure switch error
- Faulty exhaust pipe
obstruction or extractor
Exhausted flame
or lack of pellets
Er03
Fume temperature below:
55°C (Th03)
- Empty pellet tank;
- Broken thermocouple;
- Clogged pellet channel
Excess
temperature
fumes
Er05
More than 300 °C
- Room fan does not work or is
at a low power level - increase
the level to maximum (if the
problem persists call for
service)
- Insufficient draft
- Excessive dosage of pellets
- Defective smoke probe
Fume extractor
error
Er07
No rpm signal. Allows
unlocking and working by
voltage in a provisional
way P25=0
- Check connection
- Check that the fan is not
blocked
- After fault correction it is
necessary to reselect operation
mode P25=2
Fume extractor
encoder error
Er08
Encoder shows signal, but
failed regulation. Allows
unlocking and working by
voltage temporarily P25=0
- Exhaust pipe obstruction or
extractor defective
- After fault correction it is
necessary to reselect operating
mode P25=2
Содержание EARTH 9KW
Страница 10: ...9 General Measures Front Back Side Top Fire 9kW Earth 9kW Wind 9kW Figure 4 Insertable dimensions to pellets ...
Страница 35: ...34 a b Attention Do not use 90º curves c Figure 31 Examples of installations ...
Страница 101: ...100 ...
Страница 102: ...101 ...
Страница 103: ...102 ...
Страница 114: ...113 25 Annexes 25 1 Flow chart Lighting ...
Страница 115: ...114 ...
Страница 116: ...115 Disabling ...