84
Ignition failure
Er12
Maximum time:900 s and
Fume temperature less
than 50ºC
- Empty worm channel -
restart
- Burned out heating element -
replace heating element
- Firing basket incorrectly
placed
- Fume temperature did not
exceed the value set at switch-
on
Power supply
voltage cut-off
Er15
Power cut for time longer
than 50 min
- Check supply voltage with
the electric power supplier;
- Check simultaneous use of
electrical appliances
- In case of a short power
failure (<10s) the insert
continues to work normally;
- If the system was ON and the
power supply failure occurs for
more than 10s and less than
50 min the insertable develops
an ignition after blackout
Faulty
communication
with LCD control
Er16
- Check connection between
board and display
Pressure
differential
sensor damaged
Er39
The combustion regulation
is interrupted and the
stove will work with the
factory default values
entering standby until
Tfumos < 85ºC (Th28)
- Check connection between
plate and pressure differential
sensor;
- Check pressure differential
reading
- Check possible clogging in
the measurement taps, or
throttling of the same
Minimum /
reference value
for the
differential
sensor not
reached during
the CheckUp
phase
Er41
Value of 70 not reached
(FL20)
Regulation is stopped and
the greenhouse will go
into extinction
- Check connection between
plate and pressure differential
sensor;
- Check possible clogging in
the measurement taps, or
throttling of the same
Maximum/refere
nce value for
differential
sensor reached
Er42
Regulation is disrupted
and the greenhouse will go
extinct
- Check connection between
plate and pressure differential
sensor;
- Check possible clogging in
the measurement taps, or
throttling of the same
Maximum value
/ reference for
the differential
sensor reached
Servic
e
Maximum 2100 hr Hours
(T66) planned for
maintenance achieved
- Contact your installer or
repairer for occasional
preventive maintenance of the
equipment.
Содержание EARTH 9KW
Страница 10: ...9 General Measures Front Back Side Top Fire 9kW Earth 9kW Wind 9kW Figure 4 Insertable dimensions to pellets ...
Страница 35: ...34 a b Attention Do not use 90º curves c Figure 31 Examples of installations ...
Страница 101: ...100 ...
Страница 102: ...101 ...
Страница 103: ...102 ...
Страница 114: ...113 25 Annexes 25 1 Flow chart Lighting ...
Страница 115: ...114 ...
Страница 116: ...115 Disabling ...