5.5 Communication Connection
Ø
Electric meter connection diagram
Electrical Connection
Electrical Connection
5.5.2 Introduction to meter/CT Communication
Grid
Household Meter
Load
L
N
Meter1
(Single-phase meter)
Meter2
ON
OFF
PV 1
PV 2
BAT
BMS
CAN
DRM
METER/CT
COM/LCD
X1
X1
50
51
5.5.1 Introduction to DRM communication
Mode
DRM0
Operation disconnect device
Do not generate power
Requirement
DRM5
Do not generate more than 50% of rated power
DRM6
DRM7
DRM8
Do not consume power
Do not consume more than 50% of rated power
DRM1
DRM2
DRM3
DRM4
Notice!
Ø
DRM requirements( AS4777 regulatory requirements )
DRM1/5 DRM2/6 DRM3/7 DRM4/8 +3.3V DRM0 GND
GND
1
2
3
4
5
6
7
8
1
8
in out
in out
Upgrade
/
Dongle
X1-Hybrid G4 can support external control signal response, such as
complying with AS4777 regulatory requirements.
Do not generate more than 75% of rated power AND
Sink reactive power if capable
Increase power consumption
(subject to constraints from other active DRMs)
Do not consume more than 75% of rated power AND
Source reactive power if capable
Increase power generation
(subject to constraints from other active DRMs)
For AS4777 DRM function, currently only PIN6 (DRM0) and PIN1
(DRM1/5) are functional, other PIN functions are under
development.
X1-Hybrid G4 inverter should work with an electric meter or current
sensor (CT for short) to monitor household electricity usage.
The electricity meter or CT can transmit the relevant electricity data
to the inverter or platform, which is convenient for users to read at
anytime.
Users can choose to use electric meters or CTs according to demand.
Please Notice that the meter/CT brand required by SolaX must be used.
Notice!
The meter or CT must be connected to the inverter,
otherwise the inverter will shut down and alarm SolaX "meter
failure" alarm.
Smart meters must be authorized by SolaX, third party or
other companies, Unauthorized meter may be incompatible
with the inverter.
SolaX will not be responsible for the impact caused by the
use of other appliances.
Other power
generation
equipment
If the user has other power generation
equipment (such as inverter) at home and
wants to monitor both, X1-Hybrid G4 inverter
provides Meter2 communication function to
monitor the power generation equipment.
For more information, please contact SolaX.