s) EPS Setting
User can set the frequency selection in the EPS mode here, and set the
> Frequency
50Hz
EPS Setting
>Frequency
60Hz
EPS Setting
> Min SoC
10%
EPS Setting
t) Parallel Setting (a function for parallel operation)
If a parallel operation is required, the user may set it with Parallel Setting.
Parallel Setting
>
Status
Parallel Setting
Free
setting
>
Master
<
>
Status
Free
setting
Free
The “Parallel Setting” does not apply to Australia and New Zealand.
Setting
Setting
u) Reset
Users can reset the reset error log, meter power, inverter power, and restore
factory settings here.
>
Reset
Yes
Reset Error Log
>Reset
Yes
Reset Meter/CT_1
>Reset
Yes
Reset Meter/CT_2
>Reset
Yes
Reset INV Energy
>Reset
Yes
Factory Reset
>Reset
Yes
Wifi Reset
“Wifi Reset” is only supported by inverters whose 6th digit of the SN is
"A" or "C" and whose hardware has a WiFi reset circuit.
Setting failed!
Advance Password
Set OK!
Advance Password
ShutDown
>
Enable
<
ShutDown
w) MicroGrid
>
MicroGrid
Enable
MicroGrid
If the user wanna use MicroGrid, the Enable mode can be set.
v) ShutDown
ShutDown is an Enable Switch. If the user wanna use ShutDown, the
Enable mode can be set.
y) Advance Password
Here you can reset the advanced password. "Set OK!" is displayed on
success, and “Setting Failed!” will also be displayed on failure.
x) ExternalGen
The set value of power must meet the following two conditions when
the maximum charging power of batteries is to be set.
1) The value of Max Charge Power is less than that of rated power of the
generator minus total load power.
2) The value of Max Charge Power is less than or equals that of rated
power of the inverter.
Select:
ExternalGen
ExternalGen
Enable/Disable
Max Charge
5000W