Setting
Setting
>
0 0 0 0
User Password
>
Min
SOC
:
10%
Backup mode
Backup mode
>
Charge battery to
90%
>
Charge Period
Start
Time
00:00
Chrg&DischrgPeriod
>
Charge Period
End
Time
00:00
>
Allowed Disc Period
Start
Time
00:00
>
Allowed Disc Period
End
Time
00:00
>
Function Control
Enable
Chrg&DischrgPeriod2
> Mode Select
Disable
Load Management
90
91
Chrg&DischrgPeriod
>
Allowed Disc
Period
00:00
Chrg&DischrgPeriod
>
Allowed Disc
Period
End
Time
00:00
Chrg&DischrgPeriod
Start
Time
Chrg&DischrgPeriod2
Chrg&DischrgPeriod2
>
Charge Period
Start
Time
00:00
Chrg&DischrgPeriod2
>
Charge Period
End
Time
00:00
Chrg&DischrgPeriod2
g) Charge and discharge period
Here you can set the charge and discharge time period.
If two charging and discharging periods are needed, turn on the charging
and discharging period 2 and set the period.
f ) Backup mode
In this mode, you can set the power reserve percentage of the
minimum battery state, set whether the power can be taken from the
mains side to charge the battery, and set the amount of power to
charge the battery.
For example: set the reserved minimum SOC of the battery capacity to
"30%", which means that when the battery has been discharged to 10%
of the battery capacity, the battery is not allowed to continue to
discharge;
Charge battery to is set to 90%, indicating that the mains is allowed to
charge the battery at 90%.
i) User Password
The default password for the end user is "0000", where you can reset
the new password and press the up/down key to increase or decrease
the value. Press "Enter" to confirm the value and jump to the next digit.
When all passwords have been entered and confirmed, press "OK" to
set the password successfully.
h) Dry
Contact
When the user uses the inverter communication control external device
function, you can enter here to set the parameters of the external
response control. For the setting method, please refer to the user manual
of the compatible external device.
If the user uses the inverter dry contacts to control external devices (such
as heat pumps) through the Adapter box, please refer to the Adapter box
quick installation manual to set the parameters here.