Ø
CT Connection
CT connection diagram
Notice for CT connection:
Notice!
CT
Public grid
electricity
Meter/CT
LCD settings
>
Select
CT
CT/Meter Setting
Electrical Connection
Electrical Connection
1 2 3 4 5 6 7 8
1
8
1
2
3
4
5
6
7
8
485A
485B
X
CT1-2
CT1-1
CT2-2
CT2-1
X
Grid
Household Meter
Loads
L
N
X1
X1
CT 1
CT 2
ON
OFF
PV 1
PV 2
BAT
BMS
CAN
DRM
Meter/CT
COM/LCD
52
53
Upgrade
/
Dongle
L Line
CT
Public grid
electricity
Meter/CT port is at the
bottom of the inverter.
Note: The arrow on the CT
must point at the public
grid.
Meter/CT
Grid
Household Meter
Loads
L
N
Other power
generation
equipment
X1
X1
CT 1
CT 2
If the user has other power generation equipment (such as inverter) at home
and wants to monitor both, X1-Hybrid G4 inverter provides CT2
communication function to monitor the power generation equipment.
For more information, please contact SolaX.
ON
OFF
PV 1
PV 2
BAT
BMS
CAN
DRM
Meter/CT
COM/LCD
Upgrade
/
Dongle
If the user has other power generation equipment (such as inverter) at home
and wants to monitor both, X1-Hybrid G4 inverter provides CT2
communication function to monitor the power generation equipment.
For more information, please contact SolaX.
Meter/CT port is at the
bottom of the inverter.
Note: The arrow on the CT
must point at the public
grid.
Other power
generation
equipment
The current sensor measures the current on the live wire between the
inverter and the public grid.
To select CT, you need to enter Use setting, then enter CT/Meter
Setting.
Notice!
Only one of the Meter and CT connections can be
selected. Meter cable goes to pin terminal 4 and 5;
CT cable goes to pin terminal 1 and 8; reserve CT
cable goes
to pin terminal 3 and 6.
If you need this
feature, please contact us SolaX for assistance.
•
Do not place the CT on the N wire or ground wire.
• Do not put CT on the N line and L line at the same time.
• Do not place the CT on the side where the arrow points to
the inverter.
• Do not place the CT on non-insulated wires.
• The cable length between CT and inverter should not
exceed 100 meters.
• After CT is connected, prevent the CT clip from falling off.
It is recommended to wrap the CT clip around in circles with
insulating tape.