Table 2
Number of rows between
Batten U and Batten O
Roof tile type
Measurements [mm]
A
Ü
K
Total spacing
D
Batten spacing
LA
Overlap
Modules
Roof tile
Dead plate
-
Tile
2)
Tile
-
Tile
1
7
Topas 11V
150
0
0
2,387
341
132
104
Optima
150
0
0
2,377
340
138
101
Rubin 13V
1)
150
0
0
2,377
340
132
95
2
12
Optima
150
0
0
4,019
335
138
106
Rubin 13V
1)
150
0
0
4,019
335
132
100
Cosmos 12
150
0
0
4,009
334
132
92
3
17
Optima
150
0
0
5,661
333
138
108
Rubin 13V
1)
150
0
0
5,661
333
132
102
Cosmos 12
150
0
0
5,651
332
132
93
4
22
Optima
150
0
0
7,303
332
138
109
Rubin 13V
1)
150
0
0
7,303
332
132
103
Cosmos 12
150
0
0
7,293
331
132
94
Finkenberger
Pfanne
150
0
0
7,296
332
124
88
1) Water seam on the top roof tile end ground down on tiles on batten U
2) Above batten U
5.4
Horizontal module field dimensions
5.4.1
Horizontal module field dimensions
Figure 4 shows the horizontal layout of the modules and
the side groove of the SOLARWATT
roofing frame using
as an example a module field with 3 adjacently placed
modules.
Measurement H is derived from the module-covering
width 1.015 mm including the installation spacing of 2
mm between the modules.
This installation spacing should be created using two
spacers which are already stuck onto the left side of each
module.
Module field standing seam F is the spacing between the
standing seams of the roofing frame side groove and at
the same time the outermost limit for the roof tiles.
Table 3 on page 14 shows the measurements for mod
-
ule fields with a width of 12 modules.