Subject to change | © 2019 SOLARWATT GmbH | AZ-TM-PMS-1339 | Rev 001 | Version: 12/2019
Page 10
IMPORTANT
The specifi ed spacings and tolerances for the layout of the battens under the modules must be complied with
for static reasons. For batten distances under the roofi ng frame, please observe the information provided by the
relevant supplier.
NOTE
Please note for planning purposes, that the spacing between battens U and O for the module area and roof tile
area must align with each other.
You must also design the eave and ridge and adapt it together with the batten spacing LA to the circumstances
of your roof.
NOTE
NOTE
NOTE
Figure 3
Layout of battens for modules and roofi ng frame
Layout of battens for roof tiles
A Spacing between batten U and topside of supporting
board (See Chapters 5.3.1 and 5.3.4)
N Number of module rows
B Measurement of top enclosure frame
(See Chapter 5.3.2)
C Pitch length of the roof tile
K Potential shortening of the roof tile in the tile row
above the module fi eld (see Chapter 5.3.4)
Ü Potential additional overlap between roof tile and
top enclosure frame which projects 100 mm
(see Chapter 5.3.4)
Total spacing D between batten U and batten O is calculated from:
D = A + (N x 1.642 mm) + B + C - Ü - K