Subject to change | © 2019 SOLARWATT GmbH | AZ-TM-PMS-1339 | Rev 001 | Version: 12/2019
Page 6
What to do in event of transport damage
If any damage is noted, note it on the shipping papers describing each pallet in detail and take photographs as docu-
mentary evidence. Have the driver countersign these notes. If more than 10 solar modules on one pallet are damaged,
refuse to accept the pallet. Please fill out the "Transport Damage Complaint Notification" form (www.solarwatt.de) and
return it to SOLARWATT GmbH.
Please do not remove any parts or rating plates from the modules. Do not install modules if damaged.
Disposal of packaging
Please recycle the packaging (foils, straps, packing corners and the pallet). Contact the local waste management com
-
pany responsible regarding recycling.
IMPORTANT
Stacking pallets will cause damage to the SOLARWATT EasyIn Modules and must absolutely be avoided! It is
recommended that the SOLARWATT EasyIn modules are stored in a dry and frost-free place in their original pack-
aging until they are installed. Please also observe the warning notices stated on the packaging units.
Handling on the roof and the ground
SOLARWATT EasyIn modules are delivered on a pallet and are well protected by water-proof foil against the effects of
weather. The modules can be removed easily by simply lifting the two module ends. The modules must not be tilted,
because they are hooked into one another and tilting could bend the module frame.
The innovative design of the modules makes them easy to handle on the roof. The lug on the top part of the frame
enables a safe interim storage on the roof battens at any time.
3
Information about the EasyIn 60M style module
1688
1035
1015
20
47
67
1628
Overlap area
The roof construction must comply with the general requirements of the directives of the Central Association of the
German Roofing Trade (ZVDH); the system is designed for
40 x 60 mm roof battens
.