l
Diagnostics
: Displays the Isolation Status and optimizers status screens. Refer to
http://www.solaredge.us/files/pdfs/application_note_isolation_fault_
troubleshooting.pdf
.
l
AFCI
: Enables or disables arc-fault self-test. Refer to
http://www.solaredge.com/sites/default/files/arc_fault_detection_application_
note_na.pdf
l
Manual AFCI Test
: Accessible from the LCD Light button menus only. Starts a self-test for arc
http://www.solaredge.com/sites/default/files/arc_fault_detection_application_
l
Standby Mode
: Enables/disables Standby Mode - for remote commissioning.
l
Grid Protection
: Available in specific countries. Enables viewing and setting grid protection values.
l
Board Replacement
: Backs up the system parameters; Used during board replacement according to
the instructions supplied with replacement kits.
Information
Select
Information
to display the following options:
V e r s i o n s
E r r o r L o g
W a r n i n g l o g
H a r d w a r e I D s
l
Versions
: Displays inverter firmware versions:
o
ID
: The inverter ID.
o
DSP 1/2
: The DSP digital control board firmware version
o
CPU
: The communication board firmware version
NOTE
Please have these numbers ready when you contact SolarEdge Support.
l
Error Log
: Displays the last five errors.
l
Warning Log:
Displays the last five warnings.
l
Hardware IDs
: Displays the following HW serial numbers (if exist, and connected to the inverter):
o
ID
: the inverter's ID
o
RGM1
(Revenue Grade Meter): A preassembled RGM or any external electricity meter (with lower
Modbus ID)
o
RGM2
: A second external electricity meter (with the higher Modbus ID)
o
ZB
: Zigbee MAC address
o
Cell
: MEID (CDMA) or IMEI (GSM)
o
BAT1
: First battery ID
o
BAT2
: Second battery ID