StorEdge Single Phase Inverter with
Connection Unit for High Power - Technical
Specifications
StorEdge Inverter
SE7600A-US
1
Unit
Lower Power Output
Higher Power Output
OUTPUT - AC (LOADS/GRID)
Rated AC Power Output
7600
VA
Max AC Power Output
8350
VA
AC Output Voltage Min-Nom-Max (L-L)
2
211-240-264
Vac
AC Frequency Min-Nom-Max (1)
59.3 - 60 - 60.5
Hz
Maximum Continuous Output Current
@240V
32
A
GFDI
1
A
Utility Monitoring, Islanding Protection,
Country Configurable Thresholds
Yes
Charge Battery from AC (if Allowed)
Yes
THD
< 3
%
Power factor with rated power
>0.99 (configurable; 0.9 leading to 0.9 lagging)
Typical Nighttime Power Consumption
<5
W
OUTPUT - AC (BACKUP POWER)
3
Rated AC Power Output
5000
4
VA
Max AC Power Output - Surge
6600
4
VA
AC Output Voltage Min-Nom-Max (L-L)
211-240-264
Vac
AC Output Voltage Min-Nom-Max (L-N)
105-120-132
Vac
AC Frequency Min-Nom-Max
55 - 60 - 65
Hz
Maximum Continuous Output Current
@240V - Backup Mode
21
A
Max Continuous Output Current per
Phase @120V
25
A
GFDI
1
A
1
These specifications apply to inverters with part numbers SE7600A-USS2XXXXX and connection unit model number
BCU-1PH-USS.
2For other regional settings, contact SolarEdge Support.
3
Not designed for standalone applications and requires AC for commissioning.
4The rated AC power output is the minimum between the AC Power Output and the battery continuous peak power.
SolarEdge
-
StorEdge Installation Guide MAN-01-00262-1.3
110
StorEdge Single Phase Inverter with Connection Unit for High Power - Technical
Содержание SE7600A-US
Страница 1: ...SolarEdge StorEdge Solution with Backup Installation Guide For North America Version 1 3...
Страница 116: ......