SE3000H-US
SE3800H-US
SE6000H-US
SE7600H-US
SE10000H-US
SE11400H-US
UNITS
Rated AC Power in Backup Operation
(1)
3000
3800
6000
7600
10300
(2)
10300
W
7600*
10300*
AC L-L Output Voltage Range in Backup
211 - 264
Vac
AC L-N Output Voltage Range in
Backup
105 - 132
Vac
AC Frequency Range in Backup (min -
nom - max)
55 - 60 - 65
Hz
Maximum Continuous Output Current
in Backup Operation
12.5
16
25
32
42
43
A
32*
43*
GFDI
1
A
THD
<5
%
OUTPUT - SMART EV CHARGER AC
Rated AC Power
9600
W
AC Output Voltage Range
211 - 264
Vac
On-Grid AC Frequency Range (min -
nom - max)
59.3 - 60 - 60.5
Hz
(1)
Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90%
of the value stated.
(2)
With a supporting firmware version.
*Supported with PN SExxxxH-USMMxxxxxx or SExxxxH-USMNxxxxxx