EV conduit entry
- for AC connection to the Standalone EV Charger
Battery conduit entry
- for DC connection to the battery
DC Safety switch
- connects and disconnects the DC power to the system
Two communication glands: for connection of inverter communication options.
Each gland has three openings.
ON/OFF/P switch
:
ON (1)
- Turning this switch ON (after Power Optimizer pairing) starts the
operation of the power optimizers, enables power production and allows the
inverter to begin exporting power to the utility grid.
OFF (0)
- Turning this switch OFF reduces the power optimizer voltage to a low
safety voltage and inhibits exportation of power. When this switch is OFF, the
control circuitry remains powered up.
P
- Moving and releasing the switch allows viewing system information via the
LEDs, and performing the following functions:
P Position
Duration
Function
Comments
Switch moved
to P for
2
seconds
, then
released.
Displays (via
LEDs) production
information for 5
seconds, or error type
indications (if exist) for 5
seconds.
Activates the Wi-Fi
access point for
connecting to the
SetApp
While the switch is in P, all
LEDs are ON.
When the switch is released all
LEDs turn OFF for 0.5 sec and
then display the production or
error indication.
Switch moved
to P for
more
than 5 seconds
,
then released.
Starts pairing
Pairing is indicated by all 3
LEDs blinking simultaneously.
LEDs
Single Phase Energy Hub Inverter with Prism Technology MAN-01-00842-1.3
30
Inverter Interfaces
Содержание RESU10H Prime Series
Страница 81: ......