![SolarEdge RESU10H Prime Series Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/solaredge/resu10h-prime-series/resu10h-prime-series_installation-manual_1313714050.webp)
3. In the Follower inverter, connect the cable to the
2nd Inv RS485
connector.
Figure 21: Connecting two Energy Hub inverters
4. In the Leader inverter, connect the cable to either the
2nd Inv RS485
connector or
the
SMRT EV RS485
connector.
5. Pull the cables lightly to make sure they are properly connected.
6. Close the communication glands with a torque of 50 in lbs.
To connect an additional HD-Wave inverter:
1. In the HD-Wave inverter, connect one end of the communication cable to the
RS485-1
connector on the communication board. For more information, refer to the
HD-Wave inverter Installation Guide.
2. Pass the other end of the communication through Communication Gland 2 of the
Energy Hub inverter.
3. Connect the cable to the
2nd Inv RS485
connector on the communication board.
4. Pull the cables lightly to make sure they are properly connected.
5. Close the communication glands with a torque of 50 in lbs.
Chapter 5: Connecting the Inverter
49