December 2020
|
Solar Stik
®
, Inc.
54
|
System Setup and Operation Manual for the Solar Stik G-BOSS E Light HPS
PRELIMINARY
PRO-Verter Status and Alarm LEDs
Figure 43. PRO-Verter S 3000 user interface
LED INDICATIONS
Status
STATUS LED
ALARM LED
Seen during power-on sequence
Indicates completion of power-on sequence after power
On/Off button is pressed for 2 seconds (sec)
Flash 3 times
Off
Seen during power-off sequence
Indicates completion of power-off sequence after power
On/Off button is pressed for 5 s
On
On
Normal charging
Flash 1 time/sec
Off
Equalization charging
Flash 2 times/sec
Off
Inverting (discharging)
Alarm beep/3 sec (default off)
On
Off
Low battery alarm
Alarm beep/1 sec
On
Flash 1/sec
Power saving
Flash 1 time/3 sec
Off
Standby
Flash 1 time/5 sec
Off
Fault
Off
On
Table 3. User Interface LED Indicators
The Status LED indicates the operating status of
the PRO-Verter; the Alarm LED indicates a fault
has occurred; specific information about the fault
is reported on the user interface LCD screen. To
clear faults see
The
table below explains the meaning tied to each
state for both LEDs.