OPERATION OF THE DEVICE
HYD 5K...20KTL-3PH
97
Rule 0:
Enabled / Disabled
From
To
SOC
Charge
02h00m -04h00m
070%
01000W
Effective
date
Dec.22
-
Mar.21
Weekday
select
Mon. Tue. Wed. Thu. Fri. Sat. Sun.
If no rule applies, the Self-use Mode is active.
7.3.3
Timing Mode
With the Timing Mode you can define fixed times of the day to charge
or discharge the battery with a certain power.
Up to 4 rules (rule 0, 1, 2 and 3) can be set. If more than one rule is
valid for any given time, the rule with the lower number is active. Each
rule can be enabled or disabled, also charging and discharging period
for a rule can be enabled separately.
In below example, the battery will be charged with 2 kW between 22
and 4 o'clock at night, and discharged with 2,5 kW between 14 and 16
o'clock:
Timing Mode
Rule 0: Enabled / Disabled / Enabled
charge / Enabled discharge
Charge Start
22 h 00 m
Charge End
05 h 00 m
Charge Power
02000 W
DisCharge Start
14 h 00m
DisCharge End
16 h 00m