PRODUCT FEATURES
26
HYD 5K...20KTL-3PH
reach 50 A / 70 A. If you connect both battery inputs in parallel, to
increase the charging and discharging current, you can only connect 4
parallel battery systems in total with the same DC voltage (up to 100
kWh nominal capacity).
NOTE
•
If a battery input is unused, ensure to set this in the
inverter's system settings, for example:
System Settings
–
Input Channel Config
–
Bat Channel2
–
Not Used.
•
Configuration of the battery setup should only be done
when the inverter is in standby mode!
Advanced Settings
–
10. Switch on / off
–
Off