Lit. No. 76616, Rev. 02
26
November 15, 2018
SET YEAR:
Selecting the AREA position on page 2
allows the YEAR to
be set from 07 to
99 for 2007 to 2099
using the
"+"
or
"
−
"
(Reset) keys.
SET DATE:
Selecting the MODE position on page 2
allows the DATE to be set from 01 to 31
by using the
"+"
or
"
−
"
(Reset) keys.
SET TIME:
Selecting the SPEED position on page 2
allows the user to change the TIME
from 00:00 to 23:59 by using the
"+"
or
"
−
"
(Reset) keys. The LCD does not
include a colon so a decimal point is
used.
SET MONTH:
Selecting the DISTANCE position on
page 2 allows the
MONTH to be set
from 01 to 12 (Jan
to Dec) by using the
"+"
or
"
−
"
(Reset) keys.
AUTO SHUT OFF:
Selecting the TANK LEVEL
position on page 2 allows the user to turn the AUTO
SHUT OFF feature ON or OFF by using
the
"+"
or
"
−
"
(Reset) keys. While
in AUTO with the AUTO SHUT OFF
turned OFF
automatic control
will "freeze" the
current
fl
ow when HOLD is pressed. With the AUTO
SHUT OFF ON, the servo valve will run towards
closed for 4 seconds each time HOLD is selected or
ground speed is stopped. This is useful for stopping
fl
ow when using auger or belt delivery systems.
AUTO DELAY TIME:
Used to delay adjustment of
the servo valve (in AUTO) until section or
ON/OFF valves have completely
opened. Selecting the RATE position
on page 2 allows the user to change the
AUTO DELAY TIME by using the
"+"
or
"
−
"
(Reset) keys to vary the delay time
from 0 (no delay) to 1,
2, 3, or 4 seconds.
START TIME:
Selecting the VOLUME/MINUTE
position on page 2 allows the user to change the
START TIME for the
control valve. The
START TIME can be
adjusted from OFF to 2.048 seconds.
The START TIME runs the Control
Valve towards open for the amount of
time (seconds) set, when a HOLD to RUN transition
occurs. The control valve may be used to stop hydraulic
fl
ow and can be the cause of an undesirable delay
for the Servo to return to normal operating
fl
ow. The
START TIME cal value can be used to reduce this delay.
MINIMUM ALARM SPEED:
Selecting the VOLUME
position on page 2
allows adjustment of
the MINIMUM ALARM
SPEED. Pressing the
"+"
or
"
−
"
(Reset) keys will adjust the
MINIMUM ALARM SPEED from 0.1 to
99.9 mph or km/h. When the ground
speed is below the MINIMUM ALARM
SPEED, an Application Rate error will not generate
an Audible Alarm. Tank empty and Float alarms are
not disabled. Setting the MINIMUM ALARM SPEED
to OFF will disable the function and allow audible
warnings at any speed. This setting can be used to
disable nuisance alarms while stopping and starting.
"SPECIAL" CALIBRATION (CONT.)
Entering Calibration Values (cont.)
Special Calibration,
Page 2
FLOW
CAL
VOLUME
(1) (2) (3)
MIN
FLOW
VOLUME /
MINUTE
TARGET
RATE
RATE
ADJUST
RATE
TANK LEVEL
WIDTH
CAL
AREA
(1) (2) (3)
SPEED
CAL
DISTANCE
(1) (2) (3)
MODE
(ALARM RESET)
MODE
SELECT
TEST
SPEED
SPEED
(1) (2) (3)
OPERATING AND CALIBRATION INSTRUCTIONS