Lit. No. 76616, Rev. 02
17
November 15, 2018
FILLING
Filling with an external pump
1. Connect
fi
ll hose to the brine
fi
ll valve. (Opening
the valves
fi
rst will cause standing brine in the
tank to
fl
ow out.)
2. Once hose is hooked up, open the brine
fi
ll and
shut-off valves.
3. Once the valves are open, begin pumping brine
from the holding tank using the external pump.
4. Fill to the desired level.
5. Close the brine
fi
ll valve. The shut-off valve must
be open for spraying.
NOTE: After
fi
rst time
fi
lling, remove the top port
from the pump and wait for a good stream before
replacing. This will remove any air blockages.
Filling with the Liqui Maxx™ sprayer pump
NOTE: This method only works when the brine
reservoir level is above the tank level. The pump
requires a gravity-fed start to remove standing
air in the piping. Once the pump is primed it will
function normally.
1. Connect
fi
ll hose to the brine intake valve.
Opening the valve
fi
rst will cause standing brine in
the mixing tank to
fl
ow out.
2. Once the hose is hooked up, open the brine
fi
ll,
and close the shut-off valve.
3. Make sure that the servo valve is fully open.
a. HFS-100-2 (Manual Control):
Decrease
pressure to minimum with pressure toggle
switch.
b. HFD-200EX or HFD-200HYD (Auto Control):
Control should be in "HOLD" function.
4. Once brine begins to
fl
ow in, start the motor.
5. Fill tank to desired level.
6. Close the brine
fi
ll and open the shut-off valve.
Priming
Port