Lit. No. 76616, Rev. 02
29
November 15, 2018
The VOLUME, AREA, DISTANCE & SPEED data
counters maintain a running count during operation
regardless of the position of the rotary switch. When
any of these counters reach their maximum capacity,
or when you want to start a new count, the value may
be reset to zero by performing the following routine.
Counter sets may be reset independently of each other.
NOTE: If the console is locked, only Data Set 1
can be cleared.
1. Turn the sections OFF or put the system in HOLD.
2. Turn the rotary switch to VOLUME, AREA, or
DISTANCE.
3. There are three independent VOLUME counters,
paired with three AREA counters, paired with
three DISTANCE counters, and with three SPEED
Values (Average and Highest velocity). The active
set of counters is indicated by the small numbers
in the lower right area of the display (1, 2, or 3)
when the rotary switch is in the VOLUME, AREA,
or DISTANCE position. Select the set of counters
you want to RESET by pressing the "+" button.
The small number will increment each time the "+"
button is pressed (from 1 to 3, then rolls back to
1). DO NOT attempt to select the counter number
by using the "–" button, because that will clear the
active set of counters if held for 2 seconds. If the
"–" button is accidentally pressed, the console will
display "CLEAr" to alert the user that the counters
will be cleared. If the user continues to hold the "–"
button for 2 seconds "CLEAr" will disappear and
be replaced by 0.0, indicating that the selected set
of counters has been cleared.
OPERATION (CONT.)
Resetting System Counters
Display indicates that counter set #1 is selected
Display indicates that counter set #2 is selected
Display indicates that counter set #3 is selected
OPERATING AND CALIBRATION INSTRUCTIONS