Lit. No. 76616, Rev. 02
22
November 15, 2018
WIDTH CAL:
Displays the Section WIDTH in inches
for the Section selected (Unused Section must be set
to zero). The total width (sum of all Section widths)
must not exceed 65,535 inches or 65.535 meters. To
adjust a particular
section, turn that
Section switch ON
and all others OFF. If no Sections are
turned ON, it will display "NO BOOM"
to remind the user to turn a section
ON.
NOTE: The system must be in RUN to display
section numbers. Repeat this procedure for each
sec tion. Enter a value of "0" (.000) for any unused
sec tions. Your "working" width per section will be
the number of nozzles on the section times the
nozzle spacing in inches (meters). For example,
if you have 7 nozzles spaced at 20 inches, the
working width of the section is 140 inches.
NOTE: The consoles are equipped with three Section
switches. In Lane Mode the Center Section switch
is always the Primary Section and is used to de
fi
ne
the LANE WIDTH. Ag, Dust, or Turf Modes can use
any Section switch. If the operator is only using one
section, it must be the Primary Section.
NOTE: When in Lane Mode, a lane mile/kilometer is
de
fi
ned as the area in a swath equal to the Center
(Primary) Section width, that is one (1) mile/km long.
The user de
fi
nes a lane mile/kilometer by changing
the Center Section width. For example, if the Center
(Primary) Section Width is set to 12 feet, and the Left
and Right Sections are set to 3 feet, one mile traveled
will result in an Area of 1.5 lane miles covered.
ADJUST RATE:
In AUTO control with RATE selected,
pressing
"+"
or
"
−
"
will change the TARGET RATE by
the amount entered for ADJUST RATE.
This allows the
operator to make
changes to the
TARGET RATE
quickly. To disable this feature, simply enter "0" for a
val ue.
WIDTH
CAL
AREA
(1) (2) (3)
MIN FLOW:
The pur pose of this calibration setting
is to prevent the system from applying below the
recommended minimum
fl
ow rate for the nozzles.
Enter the minimum
fl
ow rate in gal
per min (li ters per
minute) based on
the nozzles being used, for the en tire
section width of the applicator. DO NOT
enter the target
fl
ow of your spray application.
For example: If the min i mum
fl
ow rate for the nozzle
you are using is .22 gal/min at their minimum
recommended pres sure and your section has
20 nozzles, enter 4.4 as the MIN FLOW value
(.22 x 20 = 4.4). The system WILL NOT ap ply at a
rate lower than this value when spraying in AUTO.
The Warning LED will FLASH whenever the system is
applying at Minimum Flow Rate but the Audible Alarm
will not sound. This value should be checked/changed
for each different nozzle that you use.
MIN
FLOW
VOLUME /
MINUTE
ADJUST
RATE
TANK LEVEL
CALIBRATION (CONT.)
Entering Calibration Values (cont.)
FLOW CAL:
This po si tion is used to cal i brate the
fl
ow me ter for ac cu rate liquid mea sure ment. Enter the
Micro-Trak liquid
cal number printed
on the
fl
owmeter
tag (
see below).
The Flow Cal number should not be
changed during operation because a
change in the Flow Cal number will also
change some counter values.
FLOW
CAL
VOLUME
(1) (2) (3)
Flowmeter Tag
OPERATING AND CALIBRATION INSTRUCTIONS
CAUTION
If spray lines are pressurized, nozzles may
spray during WIDTH calibration (below).