Lit. No. 76616, Rev. 02
24
November 15, 2018
NOTE: UNITS (English or Metric) must be set in
"Special" Calibrate before any other CALIBRATE
or "SPECIAL" CALIBRATE values.
There are three pages of "SPECIAL" CALIBRATE
values, total of 18 used for Standard Drive, selected
by the rotary switch and BLAST key. To enter Special
Cal, put the system in HOLD, turn the console power
OFF, press and hold the BLAST button while turning
console ON. The console will display SPEC for
2 seconds to show that the console is in the Special
Calibration mode. Release the BLAST button.
If the Console is unlocked, the Warning LED will
also turn ON and any of the "Special" CALIBRATE
values can be adjusted.
If the Console is locked, the Warning LED will not
turn ON and the "Special" CALIBRATE values can
only be viewed and cannot be adjusted.
NOTE: Press and release the BLAST key to
alternate between SPECIAL CAL pages 1, 2, and 3
(number icons indicate page).
The desired Special Calibration parameter(s) can then
be accessed with the rotary switch. To exit Special
Calibration, press and hold the BLAST button for
1 second. The console will save any changes and
revert to normal operation.
To exit without saving changes, simply turn the
console power OFF without pressing BLAST.
"SPECIAL" CALIBRATION
Entering Calibration Values
Special Calibration
Special Cal
Page 3
Special Cal
Page 2
Special Cal
Page 1
Manual
Enable
Minimum
Alarm
Speed
Fill Tank
Size
Start
Time
Tank Alarm
Set Point
Auto
Shut-Off
BLAST
Duration
Alarm
Enable
Auto Delay
Time
BLAST
Target Rate
Special Cal
Page 1
Special Cal
Page 2
Special Cal
Page 3
Units
(Eng/Metric)
Set Year
Vehicle
Number
Set Month
Valve
Polarity
Set Date
Valve
Speed
Set Time
OPERATING AND CALIBRATION INSTRUCTIONS