Field Name
Field Name Description
Valid Field Values
Usage Description
TEMP_1_NAME
TEMP_2_NAME
Name of temp sensor
TEXT
Function name such as Temperature
In, Temperature Out
Internal Temperature, PSU 1
Temperature, etc.
These are set by the product and are
not user settable.
TEMP_1_STATE
TEMP_2_STATE
Temperature status
OK
WARN: Low
WARN: High
FAIL : Low
FAIL: High
FAIL:Not Available
FAIL:Sensor Fault
Disabled
Temp is within operating range
Temp below normal operating range,
but not critical
Temp above normal operating range,
but not critical
Temp below normal operating range,
Critical
Temp above normal operating range,
Critical
Sensor non-detected
Sensor malfunction
Temperature detection has been
manually disabled
Each product must specify its own
operating ranges and safety
thresholds, however suggestion is that
WARN thresholds exist 5 degrees C
away from defined product FAIL
thresholds. e.g. : Product Specification
is 0-40 Degrees C, so WARN will be <=
5 and >=35.
TEMP_1_CELSIUS
TEMP_2_CELSIUS
Temperature in °C
Number
Temperature in Celsius
Temperature will be blank if the
temperature sensor is not enabled.
FAN_1_NAME
FAN_2_NAME
Name of Fan
Text
This is set by the product and are not
user settable.
FAN_1_STATE
FAN_2_STATE
Fan State
OK:Low
OK:Medium
OK:High
WARN:Max
FAIL:Stopped
FAIL:ShortCircuit
Fan is running OK. Low speed mode
Fan is running OK. Medium speed
mode
Fan is running OK High speed mode
Fan is running at maximum speed
Fan has ceased running, Critical
Fan has become short circuit, Critical
ENCLOSURE
Enclosure Name
IQH1A, IQH3A or IQH3B
Displays the name of the IQ Modular
Enclosure.
MODULE_COMMS
State of module comms bus
Number of bus errors per 20 seconds
Running average of bus errors, 0 would
indicate good comms. For IQ Modules,
this bus is I2c.
VOLTAGE_1_NAME
VOLTAGE_2_NAME
Voltage rail name
Text
For IQ these are +7.5V & -7.5V rails.
VOLTAGE_1_STATE
VOLTAGE_2_STATE
Is the voltage rail within spec?
OK
FAIL: High
FAIL: Low
Voltage rail is within spec
Absolute value of voltage rail is above
normal operating threshold
Absolute value of voltage rail is below
normal operating threshold
This definition means that if the –7V rail
is at –9V, it would be shown as
FAIL:High
Definition of out of spec is on a per
product basis. The user manual for the
product must reflect the out of spec
ranges.
VOLTAGE_1_VALUE
VOLTAGE__VALUE
The value of the voltage rail
Text
+nn.nnV
-nn.nnV
INFORMATION1
1st Information field
Text
User definable text.
INFORMATION2
2nd Information field
Text
User definable text.