IQH3A IQ 3U Modular Enclosure
www.snellgroup.com
Operation
Issue 2 Rev 2
Page 62
©
2014 Snell Limited
LOADER_VERSION=
Loader Version
Version Number
For example, 2.17 .7.
IPADDRESS
IP Address
WARN: None
WARN: Invalid Address
Numeric IP Address
No IP Address Specified
Invalid address, subnet or gateway
value specified.
IP Address of unit in Ipv4 dotted
decimal notation: xxx.xxx.xxx.xxx
MODULE_STATUS=
Module Status
OK
1 EXTRA MODULE
n EXTRA MODULES
1 MODULE MISSING
n MODULES MISSING
1 WRONG TYPE
n WRONG TYPES
where 2 <= n <= 16
Status of module type/per slot
configuration matching or Modules
mismatched / missing
SESSIONS
Control Sessions
Number
0….n – No. of connected CONTROL
sessions
LAST_MODIFIED
Last Modified
UTC Timestamp
The time a control was last modified on
a unit. Format: as per ISO 8601 for
Co-ordinated Universal Time (UTC),
i.e. YYYY-MM-DDTHH:MM:SSZ,
where the trailing “Z” indicates UTC
rather than local time.
FAULT
Internal fault status of unit
NONE
FAIL: <fault description>
This field is used to report internal
hardware or software faults detected by
a unit (as distinct from external error
conditions, e.g. loss of input).
PSU_1_NAME
PSU_2_NAME
Name of PSU
Text
Function name such as
Left PSU, Right PSU
Top PSU, Bottom PSU
PSU 1, PSU 2 etc.
These are set by the product and are
not user settable.
PSU_1_STATE
PSU_2_STATE
PSU State
OK
FAIL
FAIL: Not Fitted
Not Used
PSU is present and operating correctly
PSU presence is detected but not
operating
PSU is not fitted and the RollCall
control for the product has specified
that the PSU is fitted
PSU is not fitted and the RollCall
control for the product has specified
that the PSU is NOT fitted
RECON_STATE=
OK
Warn
Fail
0 RollNet reconnections in last 10
seconds
1 Rollnet reconnection in last 10
seconds
>1 RollNet reconnection in last 10
seconds
LAN_PORT_n_NAME
Ethernet port name as defined by the
OS
Typical example format is:
FastEthernet0/24
Where FastEthernet is the port type,
other reported types are
GigabitEthernet
0 is the interface binding and 24 is the
physical port number
On devices with only one physical
10/100 Ethernet connection the
reported string would be:
FastEthernet0/1
LAN_PORT_n_SPEED
Ethernet connection speed
10 Mbit/s Full Duplex
10 Mbit/s Half Duplex
100 Mbit/s Full Duplex
100 Mbit/s Half Duplex
1 Gbit/s Full Duplex
No Link
LAN speed in megabits per second,
and duplex mode. Use No Link when
Ethernet cable unconnected or not init.
Field Name
Field Name Description
Valid Field Values
Usage Description