IQH3A IQ 3U Modular Enclosure
www.snellgroup.com
Operation
Issue 2 Rev 2
Page 48
©
2014 Snell Limited
•
SP_TIME:
If this check box is checked then the Gateway will pass wide area
TIME messages received over the IP bridge to the RollNet network.
•
Remote IP Address:
This shows the IP address of the remote end of the IP bridge
(when connected).
•
Started By:
This shows who initiated the bridge connection. If this unit established
the connection it will show 'local' if the remote unit established the connection it will
show 'remote'.
•
Start Time:
This shows the time at which the bridge connection was established.
•
Packets Received:
This shows the number of packets received over the IP bridge.
•
Packets Sent:
This shows the number of packets transmitted over the IP bridge.
•
Connect:
This will cause the Gateway to attempt to connect the IP bridge. The
Gateway will connect to the IP address and port specified by Bridge IP Addr and
Bridge IP Port.
•
Disconnect:
This will cause the Gateway to disconnect the IP bridge. If either end of
the IP bridge is set to auto-connect the bridge, then the bridge will be immediately
re-established.
•
Connect Automatically:
If this is checked the Gateway will automatically try to
establish a bridge connection at system start-up, if the connection fails, or is manually
disconnected.
•
Active Bridge Logging:
When enabled, this function changes logging state of log
field IP_BRIDGE_STATUS to OK or FAIL instead of INFO.
Note:
Pass I_AM (Bridge) overrides both Pass I_AM (Serial) and Pass I_AM (IP). So if Pass
I_AM (Bridge) is set I AM messages will be passed over the bridge, irrespective of how the
other controls are set.
Note:
The Gateway will always use the received time stamp, whether it passes it on or not (but
see also Time from Logger).
IP_BRIDGE_STATUS
Active Logging
Inactive Logging
Connected
OK:Active
INFO:Active
Disconnected
FAIL:Inactive
INFO:Inactive