Where N is the input/(Q)SFP number and X is the lane
SFP_N_SERIAL_NR=
Displays the module serial number, which consists of an S
followed by eight digits.
SFP_N_REVISION=
Displays manufacturer revision number.
SFP_N_CONNECTOR=
Displays connector type.
TEMP_N_NAME=
Displays temperature sensor name.
TEMP_N_CELSIUS=
Displays current temperature sensor reading.
TEMP_N_STATE=
Displays temperature sensor state. Valid values are:
•
WARN: Disabled
- Temperature sensor disabled.
•
WARN: Low
- Low, but in tolerance.
•
WARN: High
- High, but in tolerance.
•
OK
•
FAIL: Low
- Low and out of tolerance.
•
FAIL: High
- High and out of tolerance.
VOLTAGE_N_NAME=
Displays voltage sensor name.
VOLTAGE_N_VALUE=
Displays current voltage reading.
VOLTAGE_N_STATE=
Displays temperature sensor state. Valid values are:
•
OK
•
WARN: Low
- Low, but in tolerance.
•
WARN: High
- High, but in tolerance.
SFP_N_WAVELENGTH=
Displays transmit wavelength in nm.
SFP_N_X_LASER_BIAS=
Displays bias level in mA.
SFP_N_X_TX_POWER=
Displays transmit power level in dBm.
SFP_N_X_TX_POWER_
STATE=
Displays transmit power level. Valid values are:
•
OK
•
WARN: Low
- Low, but in tolerance.
•
WARN: High
- High, but in tolerance.
•
FAIL: Low
- Low and out of tolerance.
•
FAIL: High
- High and out of tolerance.
SFP_N_X_RX_POWER=
Reports receive power level in dBm.
SFP_N_X_RX_POWER_
STATE=
Reports receive power level. Valid values are:
•
OK
•
WARN: Low
- Low, but in tolerance.
•
WARN: High
- High, but in tolerance.
•
FAIL: Low
- Low and out of tolerance.
•
FAIL: High
- High and out of tolerance.
Log Field